Quick answer
Seal your hygrometer in a bag with a 75% reference, either a cap of damp table salt or a Boveda 75% calibration pack, and leave it for at least 24 hours at a steady room temperature. If it reads 75%, it is accurate. If not, adjust it or note the difference and correct every reading. Recalibrate every six months.
In short
- Calibrate every new hygrometer before you trust it, even if the box says it is pre-calibrated.
- Damp table salt in a sealed bag holds the air at about 75% relative humidity.
- Wait at least 24 hours at a steady temperature, and read it without opening the bag.
- If it reads 72% in the test, add 3 points to every reading from then on.
- Even a well-calibrated hygrometer is only accurate to a few points, so watch the trend, not one number.
Every decision you make about your humidor starts with one number. Add a pack or take one out, switch from 69% to 65%, move the box to another room: all of it depends on the hygrometer telling the truth. Yet many hygrometers, including some that come fitted to new humidors, arrive several points off, and most drift over time.
This guide shows you how to check yours at home in a day, using either table salt or a Boveda calibration kit. It explains how to work out and apply a correction, where to put the hygrometer in the box, how to read it properly, and what to do when the numbers say something is wrong. It finishes with a simple log you can keep, and how we monitor our own storage at The Slow Draw.
Contents
Why your hygrometer needs calibrating
A hygrometer measures relative humidity, the amount of moisture in the air compared with the most the air could hold at that temperature. The sensors inside cheap and mid-priced hygrometers are small and sensitive. A knock in transit, months in damp air or simply age can shift their readings by several points.
Boveda, the maker of the two-way humidity packs we sell, advises calibrating every new hygrometer before use, even one sold as pre-calibrated, and recalibrating every six months. It also notes that a properly calibrated hygrometer is accurate to within about 3–5% RH. That last point matters: calibration doesn’t make a hygrometer perfect, it tells you which way and by how much it tends to be wrong.
In India, a few points can make a real difference. In the monsoon, a hygrometer reading 5% low might show 64% when the box is really at 69%, and tempt you to add moisture to cigars that are already damp. In a dry northern winter, one reading high can hide a box that is slowly drying out.
Types of hygrometer
| Type | How it works | Good to know |
|---|---|---|
| Analog dial | A needle moved by a coil or hair that reacts to moisture | Inexpensive and battery-free. Many have a small adjustment screw on the back. Can stick or drift; tap gently before reading |
| Digital | An electronic sensor with a display, usually showing temperature too | Easier to read and generally steadier. Some let you set an offset; others need you to note the correction yourself |
| Wireless or app-linked sensor | A digital sensor that sends readings to your phone | Records history, so you see the pattern rather than one reading. Still needs calibrating like any other |
Whichever you use, a hygrometer that also shows temperature is worth having, because humidity and temperature always need to be read together. Our acrylic humidor comes with a digital hygrometer fitted.
Choosing a hygrometer worth calibrating
Calibration can correct a steady error, but it can’t rescue a sensor that wanders. When you buy or replace a hygrometer, look for:
- Temperature as well as humidity on the same display, so you can read both together.
- A clear, steady display you can read without opening the lid, if the humidor has a window.
- An offset or calibration setting on digital models, so you don’t have to correct every reading in your head.
- A replaceable battery, and a low-battery warning. Weak batteries can make some digital sensors misread.
- History, if you can. App-linked sensors that record readings over days are the easiest way to see what happens during a power cut or a storm.
- A size that fits among the cigars without crushing them or blocking the lid.
Price is only a rough guide. An inexpensive digital hygrometer that holds the same correction for months is more useful than an expensive one that drifts.
When to calibrate
- When it is new, before the cigars go in.
- Every six months after that. Boveda’s guidance is twice a year.
- Before the monsoon and before winter, when you are about to change your packs.
- After a drop or a knock, or after it has been left somewhere very hot or very damp.
- When the reading and the cigars disagree. If the hygrometer says 68% but the cigars feel spongy or brittle, trust the cigars and check the instrument.
- When you move it to a different box, so you start with a known correction.
Signs your hygrometer may be wrong
You don’t have to wait six months to suspect a problem. These signs suggest the hygrometer needs testing now:
- The reading hasn’t moved at all for weeks, through rain, dry spells and pack changes.
- It sits on a suspiciously round number, such as exactly 70%, every time you look.
- It shows something impossible for a closed box with a two-way pack, like 90% or 40%.
- An analog needle jumps when you tap the glass.
- The cigars feel spongy while the hygrometer says the box is dry, or brittle while it says the box is damp.
- Two hygrometers in the same box disagree by more than a few points.
Method 1: the salt test
The salt test uses a simple piece of chemistry. Air sealed above a damp mix of ordinary salt and water settles at about 75% relative humidity at room temperature. This is a well-measured reference point: a classic study of humidity fixed points published by the US National Bureau of Standards (now NIST) puts saturated sodium chloride at about 75.5% RH at 20°C and about 75.3% at 25°C. That is close enough to 75% for checking a humidor hygrometer.
What you need
- Plain table salt, about a tablespoon.
- A small cap or lid, such as a bottle cap or the lid of a small jar.
- A little water. Distilled or filtered water is best, but tap water works.
- A zip-lock bag large enough to hold the cap and the hygrometer, or an airtight plastic box.
- Your hygrometer.
Step by step
- Fill the cap with salt.
- Add water a few drops at a time and mix until the salt looks like damp sand. It should be wet all through, with no puddle on top. You are not trying to dissolve the salt.
- Place the cap and the hygrometer in the bag, side by side. Keep the salt from touching or spilling onto the sensor.
- Seal the bag fully, so no room air can get in.
- Leave it somewhere with a steady temperature: an inside room, out of direct sun, away from the AC’s airflow and the kitchen.
- Wait at least 24 hours. The reading can take hours to settle, and a longer wait gives a more reliable result.
- Read the hygrometer through the bag, without opening it. Write down the reading and the date.
Mistakes that spoil a salt test
- Too much water. A salty puddle is no longer a reliable reference. Damp sand is what you want.
- Salt on the sensor. Salt crystals on a hygrometer’s vents can damage it or skew the reading.
- A leaky bag. Squeeze the seal shut along its whole length and check it again before you leave it.
- Moving the bag. Carrying it from an air-conditioned room to a warm one mid-test changes the reading. Leave it in one place.
- Reading too early. A reading after an hour or two often hasn’t settled yet.
- Opening the bag to look. The moment room air gets in, the reading starts moving away from 75%.
Method 2: a Boveda 75% calibration kit
If you prefer not to mix salt, Boveda makes a hygrometer calibration kit: a resealable bag with a 75% Boveda pack already inside. Boveda’s steps are simple:
- Put the hygrometer or sensor inside the bag and reclose the zip fully.
- Leave it for at least 24 hours in a room between about 18°C and 24°C (65–75°F).
- If it reads 75%, the hygrometer is accurate. If it reads higher or lower, either note the difference as your correction for future readings, or adjust the hygrometer to 75% and repeat the test.
- To use the kit again, reseal the bag with the pack inside. Boveda says to use it again within three months.
The kit and the salt test give you the same reference point. The kit is tidier and harder to get wrong; the salt test costs almost nothing and can be done tonight with what is in your kitchen.
Working out your correction
Your correction, often called an offset, is simply the difference between 75 and what your hygrometer showed in the test:
Correction = 75 − test reading
Add the correction to every reading from then on. If the correction is negative, adding it means subtracting. Use percentage points, not percentages: a hygrometer that reads 72% in the test is 3 points low, so you add 3 points, not 3%.
| Test reading | Correction | Humidor shows | Real humidity |
|---|---|---|---|
| 75% | 0 | 68% | 68% |
| 72% | +3 | 66% | 69% |
| 78% | −3 | 70% | 67% |
| 70% | +5 | 64% | 69% |
| 81% | −6 | 72% | 66% |
Write the correction and the date on a small sticker on the back of the hygrometer, for example “+3, checked 15 June”. Six months later you will know at a glance whether it has drifted further.
If the correction is larger than about 5 points, think about replacing the hygrometer. A big error often means a tired sensor, and a tired sensor rarely drifts by the same amount every month.
Adjusting an analog or digital hygrometer
Analog dials often have a small screw or dial on the back that turns the needle. The difficulty is that the reading starts to change the moment you take the hygrometer out of the bag. Some people adjust it inside a large bag; most find it easier to leave the needle alone and keep a written correction instead.
Digital hygrometers sometimes have a calibration or offset setting, usually reached by holding one or two buttons. Follow the maker’s manual exactly. If yours has no such setting, keep the correction on the sticker and apply it in your head.
App-linked sensors usually let you set an offset in the app. Set it after the test, then run the test again a day later to confirm the app now shows 75%.
A worked example: calibrating before the monsoon
Imagine a smoker in Mumbai getting ready for the rains in late May. Their humidor’s digital hygrometer has read a steady 63% for weeks, and they are about to add a 72% pack to bring it up.
First, they run a salt test. After 24 hours in the sealed bag, the hygrometer shows 71%. The correction is 75 − 71 = +4 points. That means the humidor’s “63%” is really about 67%, comfortably inside the 65–70% range.
Adding a 72% pack would have pushed a correctly stored box towards the damp end just as the monsoon arrived. Instead, they write “+4, checked late May” on the back of the hygrometer, switch to fresh 65% packs for the season, and keep checking weekly. When the corrected reading creeps to 70% in July, they know it’s the weather, not the instrument, and move the box to a cooler room.
One salt test changed the whole season’s decisions. That is the real value of calibration.
One test point, not the whole range
Both the salt test and the Boveda kit check your hygrometer at a single point, 75%. Your humidor lives a few points lower, at 65–70%. For most hygrometers the error at 75% is a good guide to the error at 68%, so the correction carries over well enough for cigar storage.
It is not a laboratory calibration, though, and a sensor can be slightly more or less wrong at other humidities. That is one more reason to trust the cigars alongside the number. If your corrected reading says 68% and the cigars feel right in the pinch test, burn evenly and draw well, your storage is doing its job.
Where to put the hygrometer in your humidor
- Among the cigars, not right next to the humidity pack. A sensor resting on the pack reads the pack, not the box.
- Mid-height in a tall box. In a wine cooler or cabinet with several shelves, a middle shelf gives the most representative reading; a second sensor on another shelf shows how even the cabinet is.
- Away from the lid seal and hinges, where a little room air can leak in.
- In the same place every time. Moving the hygrometer around changes the reading even if the box hasn’t changed.
Hygrometers in wine coolers and large cabinets
A converted wine cooler or a cabinet behaves differently from a desktop humidor. The cooling system runs in cycles, and each cycle can pull moisture out of the air and then let it recover. Temperature also varies from shelf to shelf, so humidity does too.
For these, two calibrated sensors are better than one: one on a middle shelf and one near the top or bottom. Test both in the same salt bag at the same time, note each one’s correction, and label them so you never mix them up. If the two corrected readings stay a few points apart, that is the cabinet telling you it isn’t even, and the drier or damper shelf needs more or fewer packs.
Read cabinets at the same point in the cooling cycle each time, or better still, use sensors that record over a day. One reading taken just after the compressor switches off can look very different from one taken an hour later.
Testing several hygrometers at once
You can calibrate several hygrometers in one large bag or airtight box with a single cap of damp salt, as long as none of them touches the salt and the container is sealed. It is also the easiest way to settle an argument between two instruments: after 24 hours, the one closer to 75% is the one to trust.
Reading the number properly
A humidor reading is only meaningful when the box has had time to settle. Opening the lid lets room air in, and the number jumps up or down for a while afterwards. Close the box and wait at least half an hour, better an hour, before you trust the reading.
Temperature changes the reading too. Relative humidity describes moisture compared with what the air can hold at that temperature, so the same box of air shows a higher RH when it cools and a lower RH when it warms. A humidor that reads 66% on a warm afternoon may read 69% at night with the AC on, without any moisture coming in or going out. Read at the same time of day each week, and always note the temperature beside the humidity.
What should you see? For home storage we recommend 65–70% RH at 18–21°C, with the room ideally between 19°C and 23°C. Above about 24°C for long periods, tobacco beetle eggs can hatch, whatever the humidity. You can read more in How to store cigars in India.
Keeping a simple storage log
A log turns single readings into a pattern. It doesn’t need to be elaborate. Once a week, write down:
- the date and time;
- the corrected humidity and the temperature;
- anything that happened since the last check: packs replaced, a storm, a long power cut, the box moved, the lid left open;
- how the cigars felt in the pinch test.
After a month, look at the four readings together. A slow climb through the monsoon tells you to switch to 65% or move the box. A sudden drop after a holiday tells you the AC was off. A steady line tells you to leave well alone. Part VI of The Companion, our free cigar journal, includes a log you can print and keep beside the humidor.
When the numbers are off: what to do
| What you see | Likely causes | What to try |
|---|---|---|
| Stays above 72% | Damp room, extra humidifiers, wrong pack strength | Remove other humidifiers, use fresh 65% packs, move the box to a cooler, drier room |
| Stays below 62% | Too few packs, dry new cedar, loose lid, packs worn out | Add packs (go by capacity), check the lid seal, season new wood, try 72% in a dry winter |
| Swings by several points daily | AC switching on and off, a sunny spot, frequent opening | Move the box out of the sun and airflow, open it less often, read at the same time each week |
| Two hygrometers disagree | One or both need calibrating, or they sit in different spots | Test both in the same bag, then place them side by side for a day |
| Reading looks right but cigars feel wrong | Hygrometer error | Calibrate it; trust the cigars until you have |
Looking after your hygrometer
- Keep the sensor vents clear of tobacco dust and salt.
- Don’t wipe it with a wet cloth or spray anything near it.
- Change the batteries before they run flat, and recheck the calibration afterwards if the readings jump.
- Keep it from resting directly on a humidity pack.
- If it is ever soaked or dropped hard, test it again before you rely on it.
How we monitor storage at The Slow Draw
Our shop storage cabinets run at 65–70% RH and 18–21°C, the same range we recommend for home humidors. Before any order ships, we open the box and check the cigars for humidity, cracked wrappers and construction, then pack them in a sealed pouch with a Boveda humidity pack.
For customers who want us to keep their cigars, The Slow Draw Vault holds boxes in a compressor-cooled cabinet at 17°C (±1°) and 65–68% RH, monitored by loggers with alarms and on backup power. Each box is opened and looked over every quarter for wrapper condition, mould and beetle signs, and each month’s conditions appear in your Vault ledger. Our Vault terms set out the details.
Explore next
How to store cigars in India, our Boveda store and humidors.
Frequently asked questions
How often should I calibrate my hygrometer?
Before you first use it, then every six months, as Boveda recommends. Check it again after a drop, or whenever the reading and the feel of the cigars disagree.
How long does the salt test take?
Leave the hygrometer sealed with the damp salt for at least 24 hours at a steady room temperature. Readings taken after only an hour or two are often still settling.
Does it matter what kind of salt I use?
Use plain table salt. What matters most is that the salt is damp all through, like wet sand, with no puddle on top.
My hygrometer read 80% in the salt test. What now?
It reads 5 points high, so subtract 5 from every reading. If the error grows at your next check, replace the hygrometer.
Is a digital hygrometer more accurate than an analog one?
Often, but not always. Any hygrometer can be off, which is why every one needs calibrating. A calibrated analog dial is more useful than an uncalibrated digital one.
Will a calibrated hygrometer give me an exact reading?
No. Boveda puts a properly calibrated hygrometer at about 3–5% RH. Use the reading together with the temperature and the feel of the cigars.
Can I calibrate the hygrometer inside my humidor?
No. The humidor isn’t a fixed reference; its humidity moves. Calibrate in a sealed bag with salt or a 75% calibration pack, then put the hygrometer back in the box.
Why does my reading change when I open the lid?
Room air rushes in and mixes with the air in the box. Close the lid and wait at least half an hour before you read it again.
For adult readers. Tobacco use is harmful to health; this guide is about storage, not safety of use.




0 Comments
No comments yet. Start the conversation.
Please log in to join the discussion.